WEKO3
-
RootNode
アイテム
チタン合金の表面処理条件が硬質レジンとの接着耐久性に及ぼす影響
https://ohu-lib.repo.nii.ac.jp/records/2149
https://ohu-lib.repo.nii.ac.jp/records/2149c149ba25-f853-4a23-b4ff-d9ef11b1b46a
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS)_JAIRO Cloud(WEKO3)対応_596d4a9f(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-06-30 | |||||
タイトル | ||||||
タイトル | チタン合金の表面処理条件が硬質レジンとの接着耐久性に及ぼす影響 | |||||
タイトル | ||||||
タイトル | The Effect of Surface Treatment on Adhesion Durability of Lightcured Facing Resin to Ti Alloys | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Ti-40Zr alloy | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | lightcured facing resin | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | adhesion durability | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | titanate coupling agent | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | heat treatment | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
記事種別(日) | ||||||
値 | 原著論文 | |||||
記事種別(英) | ||||||
言語 | en | |||||
値 | Original Article | |||||
著者名(日) |
今井, 博史
× 今井, 博史 |
|||||
著者名よみ |
イマイ, ヒロシ
× イマイ, ヒロシ |
|||||
著者名(英) |
IMAI, Hiroshi
× IMAI, Hiroshi |
|||||
著者所属(日) | ||||||
値 | 奥羽大学歯学部歯科理工学講座 | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Department of Dental Materials Science, Ohu University School of Dentistry | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The purpose of this study was to examine the effect of surface treatment on adhesion durability of lightcured facing resin to Ti alloy and compared with that of PT to know its possible application as a facing resin crown. In this experiment, Ti-40Zr alloy(TZ), Pure Ti (PT), 3 kinds of facing resins and 2 kinds of coupling agents were used. For the surface treatment of casting specimen, 5 conditions were set up including a control condition using a facing resin-attached primer and 4 test conditions using titanate, silane coupling treatment, heat treatment and titanate +heat treatment. While the formation of resin was performed with an exclusive metal casting, the adhesion specimen thus obtained was submitted to a thermal cycling test at 0 to 20000 followed by shear bond test to examine its adhesion durability. The results obtained were as follows. 1. TZ showed a superior corrosion resistance with larger modulus of elasticity, elastic limit, and tensile strength and less elongation. 2. No relationship was observed between mechanical strength and adhesion durability of facing resin to TZ and PT in a thermal cycling test. 3. As for the bond strength in relation to varied metal surface treatments, heat treatment and titanate coupling agent +heat treatment showed a larger value compared with other treatments irrespective of the kind of resin or frequency of thermal cycling. 4. No significant difference was observed in the bond strength between TZ and PT under any of the varied conditions examined. From the evidences mentioned above and taking its chemical and mechanical properties into consideration as well, it is suggested that TZ has more expected clinical utility as a facing resin crown than PT and that heat treatment of alloy is essential for ensuring the improved adhesion durability to a facing resin. | |||||