WEKO3
-
RootNode
アイテム
固形根管充填材の諸性質
https://ohu-lib.repo.nii.ac.jp/records/2357
https://ohu-lib.repo.nii.ac.jp/records/2357033f041e-7cd8-4320-a46b-a8560da1aee0
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文(ELS)_JAIRO Cloud(WEKO3)対応_596d4a9f(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-03-31 | |||||
タイトル | ||||||
タイトル | 固形根管充填材の諸性質 | |||||
タイトル | ||||||
タイトル | The Properties of Solid Root Canal Filling Materials | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | water absorption | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | adhering gas | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | structure of gutta-percha point | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
記事種別(日) | ||||||
値 | 原著論文 | |||||
記事種別(英) | ||||||
言語 | en | |||||
値 | Original Article | |||||
著者名(日) |
五十畑, 正憲
× 五十畑, 正憲 |
|||||
著者名よみ |
イソハタ, マサノリ
× イソハタ, マサノリ |
|||||
著者名(英) |
ISOHATA, Masanori
× ISOHATA, Masanori |
|||||
著者所属(日) | ||||||
値 | 奥羽大学大学院歯学研究科歯内歯周療法学専攻 | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Ohu University Graduate School of Dentistry, Endodontics and Periodontics Major | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | In endodontics, final treatment of pulpectomy and infected root canal is root canal filling. As for root canal obturating points, miscellaneous properties are required. Although JIS specifies appearance, injurious action, shape and size, fracture resistance, radio-opacity and post disinfection quality, many other properties have been left uninvestigated. In this study, water absorption, surface and internal structure, organic-inorganic component ratio, gas amount left adhering to the point after aeration and the effect of adhering gas on Escherichia coli cultivation were investigated on the commercially available six points. The findings were as follows. The amount of water absorption of the individual point was proportional to the adhering amount of gas. The more porous the structure of the point was the more water absorption there was. The amount of gas left adhering to the point didn't disinfect Escherichia coli. This fact suggests that the obturating point could be effectively gas sterilized at 37℃ and used with biological safety. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN1010214X | |||||
書誌情報 |
奥羽大学歯学誌 巻 32, 号 1, p. 19-27, 発行日 2005-03-31 |