WEKO3
アイテム
{"_buckets": {"deposit": "41079ca2-132f-4c0a-ae33-88f3cde7cb92"}, "_deposit": {"created_by": 3, "id": "2399", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "2399"}, "status": "published"}, "_oai": {"id": "oai:ohu-lib.repo.nii.ac.jp:00002399", "sets": ["103"]}, "author_link": ["9011", "9012", "9013"], "item_1_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-06-30", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "121", "bibliographicPageStart": "111", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "奥羽大学歯学誌"}]}]}, "item_1_creator_6": {"attribute_name": "著者名(日)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "浅井, 政一"}], "nameIdentifiers": [{"nameIdentifier": "9011", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_creator_7": {"attribute_name": "著者名よみ", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "アサイ, マサカズ"}], "nameIdentifiers": [{"nameIdentifier": "9012", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_creator_8": {"attribute_name": "著者名(英)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "ASAI, Masakazu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "9013", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_type": "Other"}]}, "item_1_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "This study was carried out to find out whether embresure clasp has a support ability on the movement of an abutment tooth of the partial denture under the condition of alveoral bone resorption. Two types of chrome-cobalt removable partial denture castings were fabricated on a mandibular test model simulating a free-end saddle. The compornent parts of each casting were Akers\u0027 clasp or embresure clasp on an abutment tooth, indirect retainers (Akers\u0027 clasps on teeth Nos. 44 and 47), a lingual bar and a metal base with loading platform. The height of the alveoral bone portion around the abutment tooth was set in two positions, which were at no reduction and 1/4 reduction, respectively. The partial denture castings were seated with a 2 kgf load by a loading apparatus. The movement of the abutment tooth was measured at a higher magnification using an indicator rod attached to the occlusal surface of the tooth. The Sirognatho analyzer system was used to analyze the direction and magnitude of abutment tooth movement. The results were as follows : The direction of abutment tooth movement by the load was mesial when observed in the mesio-distal direction. 2. When observed in the bucco-lingual direction, the abutment tooth movement on both direct retainer was mesio-lingual direction under the alveoral ridge crest load and the lingual load respectively, but the one under the buccal load showed mesio-buccal movement. 3. Abutment tooth movement increased according to the reduction of the alveoral bone portion. The distance of abutment tooth movement with embresure clasp was smaller than that with Akers\u0027 clasp. These results suggested that embresure clasp would be efficient as a direct retainer for the abutment tooth under the condition of alveolar bone resorption.", "subitem_description_type": "Other"}]}, "item_1_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN1010214X", "subitem_source_identifier_type": "NCID"}]}, "item_1_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Department of Prosthetic Dentistry, Ohu University School of Dentistry"}]}, "item_1_text_2": {"attribute_name": "記事種別(日)", "attribute_value_mlt": [{"subitem_text_value": "原著論文"}]}, "item_1_text_3": {"attribute_name": "記事種別(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "Original Article"}]}, "item_1_text_9": {"attribute_name": "著者所属(日)", "attribute_value_mlt": [{"subitem_text_value": "奥羽大学歯学部歯科補綴学講座"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2005-06-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00004193765.pdf", "filesize": [{"value": "1.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1400000.0, "url": {"url": "https://ohu-lib.repo.nii.ac.jp/record/2399/files/KJ00004193765.pdf"}, "version_id": "4f7dd957-1caa-4972-9038-46467c53daa5"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "distal-extension removable partial denture", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "abutment tooth movement", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "support ability of abutment tooth embresure clasp", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "下顎片側遊離端義歯における支台歯の挙動に対する双子鉤", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "下顎片側遊離端義歯における支台歯の挙動に対する双子鉤"}, {"subitem_title": "Effect of Embresure Clasp on Abutment Tooth Movement of Lower Distal-extention Removable Partial Denture", "subitem_title_language": "en"}]}, "item_type_id": "1", "owner": "3", "path": ["103"], "permalink_uri": "https://ohu-lib.repo.nii.ac.jp/records/2399", "pubdate": {"attribute_name": "公開日", "attribute_value": "2005-06-30"}, "publish_date": "2005-06-30", "publish_status": "0", "recid": "2399", "relation": {}, "relation_version_is_last": true, "title": ["下顎片側遊離端義歯における支台歯の挙動に対する双子鉤"], "weko_shared_id": -1}
下顎片側遊離端義歯における支台歯の挙動に対する双子鉤
https://ohu-lib.repo.nii.ac.jp/records/2399
https://ohu-lib.repo.nii.ac.jp/records/2399fcbc478d-fbf6-4c70-a7b0-bb802ecaa044
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00004193765.pdf (1.4 MB)
|
|
Item type | 紀要論文(ELS)_JAIRO Cloud(WEKO3)対応_596d4a9f(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2005-06-30 | |||||
タイトル | ||||||
タイトル | 下顎片側遊離端義歯における支台歯の挙動に対する双子鉤 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Effect of Embresure Clasp on Abutment Tooth Movement of Lower Distal-extention Removable Partial Denture | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | distal-extension removable partial denture | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | abutment tooth movement | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | support ability of abutment tooth embresure clasp | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
記事種別(日) | ||||||
値 | 原著論文 | |||||
記事種別(英) | ||||||
言語 | en | |||||
値 | Original Article | |||||
著者名(日) |
浅井, 政一
× 浅井, 政一 |
|||||
著者名よみ |
アサイ, マサカズ
× アサイ, マサカズ |
|||||
著者名(英) |
ASAI, Masakazu
× ASAI, Masakazu |
|||||
著者所属(日) | ||||||
値 | 奥羽大学歯学部歯科補綴学講座 | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Department of Prosthetic Dentistry, Ohu University School of Dentistry | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | This study was carried out to find out whether embresure clasp has a support ability on the movement of an abutment tooth of the partial denture under the condition of alveoral bone resorption. Two types of chrome-cobalt removable partial denture castings were fabricated on a mandibular test model simulating a free-end saddle. The compornent parts of each casting were Akers' clasp or embresure clasp on an abutment tooth, indirect retainers (Akers' clasps on teeth Nos. 44 and 47), a lingual bar and a metal base with loading platform. The height of the alveoral bone portion around the abutment tooth was set in two positions, which were at no reduction and 1/4 reduction, respectively. The partial denture castings were seated with a 2 kgf load by a loading apparatus. The movement of the abutment tooth was measured at a higher magnification using an indicator rod attached to the occlusal surface of the tooth. The Sirognatho analyzer system was used to analyze the direction and magnitude of abutment tooth movement. The results were as follows : The direction of abutment tooth movement by the load was mesial when observed in the mesio-distal direction. 2. When observed in the bucco-lingual direction, the abutment tooth movement on both direct retainer was mesio-lingual direction under the alveoral ridge crest load and the lingual load respectively, but the one under the buccal load showed mesio-buccal movement. 3. Abutment tooth movement increased according to the reduction of the alveoral bone portion. The distance of abutment tooth movement with embresure clasp was smaller than that with Akers' clasp. These results suggested that embresure clasp would be efficient as a direct retainer for the abutment tooth under the condition of alveolar bone resorption. | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN1010214X | |||||
書誌情報 |
奥羽大学歯学誌 巻 32, 号 2, p. 111-121, 発行日 2005-06-30 |