WEKO3
アイテム
{"_buckets": {"deposit": "f1518d54-8f8f-414b-b6bf-9a2ca176ca31"}, "_deposit": {"created_by": 3, "id": "3855", "owners": [3], "pid": {"revision_id": 0, "type": "depid", "value": "3855"}, "status": "published"}, "_oai": {"id": "oai:ohu-lib.repo.nii.ac.jp:00003855", "sets": ["239"]}, "author_link": ["13106", "13104", "13102", "13100", "13105", "13098", "13099", "13101", "13103"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4号", "bibliographicPageStart": "231-239", "bibliographicVolumeNumber": "39巻", "bibliographic_titles": [{"bibliographic_title": "奥羽大学歯学誌"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "小型血液ガス分析装置のABL77(ラジオメーター社)とi-stat 300(扶桑薬品工業)の精度について検討するため、全身麻酔患者8名から採取した動脈血45検体を用い、従来の据え置き型血液ガス分析装置ABL510(ラジオメーター社)と比較した。精度評価として系列ごとの全データから標準誤差を求め、その範囲から逸脱したデータの割合を逸脱率とした。各装置によるpH、PaCO2、PaO2、SaO2、HCO3-、Hb、Na+、K+、Ca2+の測定結果を検体ごとに列記し、逸脱率および平均値を示した。総合的な逸脱率は、ABL510が4%で、ABL77は1%、i-statは0.3%であった。なおNa+、K+、Ca2+は新型2機種でのみ計測可能のため、逸脱率の比較は出来なかった。i-statはHbの検査において2.2%の逸脱がみられたのみで、酸塩基平衡や血液ガス分析での逸脱は全くなかった。", "subitem_description_type": "Abstract"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0916-2313", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小松, 泰典"}], "nameIdentifiers": [{"nameIdentifier": "13098", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田, 健司"}], "nameIdentifiers": [{"nameIdentifier": "13099", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "冨田, 修"}], "nameIdentifiers": [{"nameIdentifier": "13100", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福島, 雅啓"}], "nameIdentifiers": [{"nameIdentifier": "13101", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "八木下, 健"}], "nameIdentifiers": [{"nameIdentifier": "13102", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "赤沼, 龍一"}], "nameIdentifiers": [{"nameIdentifier": "13103", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 史彦"}], "nameIdentifiers": [{"nameIdentifier": "13104", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川合, 宏仁"}], "nameIdentifiers": [{"nameIdentifier": "13105", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山崎, 信也"}], "nameIdentifiers": [{"nameIdentifier": "13106", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2014-10-16"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "S39(4)231-239.pdf", "filesize": [{"value": "2.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2200000.0, "url": {"label": "S39(4)231-239.pdf", "url": "https://ohu-lib.repo.nii.ac.jp/record/3855/files/S39(4)231-239.pdf"}, "version_id": "c24e7596-6b92-4195-93e6-155d58a4ecc3"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Calcium(血液); Potassium(血液); Sodium(血液); *機器と資材用品; *血液ガス分析; Hemoglobins; 酸素(血液); 水素イオン濃度; 重炭酸塩; 二酸化炭素(血液)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "動脈血酸素分圧", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ヒト; 歯学", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "小型血液ガス分析装置の比較使用経験", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "小型血液ガス分析装置の比較使用経験"}]}, "item_type_id": "10002", "owner": "3", "path": ["239"], "permalink_uri": "https://ohu-lib.repo.nii.ac.jp/records/3855", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-10-16"}, "publish_date": "2014-10-16", "publish_status": "0", "recid": "3855", "relation": {}, "relation_version_is_last": true, "title": ["小型血液ガス分析装置の比較使用経験"], "weko_shared_id": -1}
小型血液ガス分析装置の比較使用経験
https://ohu-lib.repo.nii.ac.jp/records/3855
https://ohu-lib.repo.nii.ac.jp/records/38552583ad99-14bc-49c0-ad0c-d077cf934901
名前 / ファイル | ライセンス | アクション |
---|---|---|
S39(4)231-239.pdf (2.2 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-10-16 | |||||
タイトル | ||||||
タイトル | 小型血液ガス分析装置の比較使用経験 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Calcium(血液); Potassium(血液); Sodium(血液); *機器と資材用品; *血液ガス分析; Hemoglobins; 酸素(血液); 水素イオン濃度; 重炭酸塩; 二酸化炭素(血液) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 動脈血酸素分圧 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ヒト; 歯学 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
小松, 泰典
× 小松, 泰典× 吉田, 健司× 冨田, 修× 福島, 雅啓× 八木下, 健× 赤沼, 龍一× 鈴木, 史彦× 川合, 宏仁× 山崎, 信也 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 小型血液ガス分析装置のABL77(ラジオメーター社)とi-stat 300(扶桑薬品工業)の精度について検討するため、全身麻酔患者8名から採取した動脈血45検体を用い、従来の据え置き型血液ガス分析装置ABL510(ラジオメーター社)と比較した。精度評価として系列ごとの全データから標準誤差を求め、その範囲から逸脱したデータの割合を逸脱率とした。各装置によるpH、PaCO2、PaO2、SaO2、HCO3-、Hb、Na+、K+、Ca2+の測定結果を検体ごとに列記し、逸脱率および平均値を示した。総合的な逸脱率は、ABL510が4%で、ABL77は1%、i-statは0.3%であった。なおNa+、K+、Ca2+は新型2機種でのみ計測可能のため、逸脱率の比較は出来なかった。i-statはHbの検査において2.2%の逸脱がみられたのみで、酸塩基平衡や血液ガス分析での逸脱は全くなかった。 | |||||
書誌情報 |
奥羽大学歯学誌 巻 39巻, 号 4号, p. 231-239, 発行日 2012-12 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0916-2313 |