@article{oai:ohu-lib.repo.nii.ac.jp:00002747, author = {藤原, 治 and 佐々木, 重夫 and 天野, 義和 and フジワラ, オサム and ササキ, シゲオ and アマノ, ヨシカズ and FUJIWARA, Osamu and SASAKI, Shigeo and AMANO, Yoshikazu}, issue = {1}, journal = {奥羽大学歯学誌}, month = {Jan}, note = {P(論文), Because root canal preparation in root canal treatment takes long time, various special contraangle handpiece are developed to promote efficiency of root canal preparation. Root canal are prepared with computerized micro motor handpiece. The purpose of this study is to examine the time of root canal preparation and the difference of sealing efficiency of root canal fillings between exclusive point and other point after preparation in the cases of files Endo and motor technika vision, and to find their advantage and problem. The results obtained in the case of root canal preparation with Endo motor tecnika were as follows. 1. Time of root canal preparation was shorter than in the case of hand files. 2. Time of the preparation was almost the same irrespective of the difference in the root canal curve. 3. The tip of files tends to deviate from the root apex for root canals with great curvature. 4. Sealing efficiency was maintained without exclusive point. It is suggested that the pressure in preparation should also be taken into account and that the necessity of practices using teeth models should be taken into account.}, pages = {35--43}, title = {エンドモーターテクニカヴィジョンを用いた根管形成と根管充填の封鎖性に関する研究}, volume = {35}, year = {2008} }