@article{oai:ohu-lib.repo.nii.ac.jp:00002751, author = {田中, 久 and 鈴木, 陽典 and 島田, 敏尚 and 福井, 和徳 and 氷室, 利彦 and タナカ, ヒサシ and スズキ, ヨウスケ and シマダ, トシナオ and フクイ, カズノリ and ヒムロ, トシヒコ and TANAKA, Hisashi and SUZUKI, Yousuke and SHIMADA, Toshinao and FUKUI, Kazunori and HIMURO, Toshihiko}, issue = {1}, journal = {奥羽大学歯学誌}, month = {Jan}, note = {P(論文), Radiation exposure was compared among four imaging techniques : Limited Conebeam X-ray CT (3DX-FPD) ; spiral CT (CT) ; panoramic X-ray (panoramic) ; and occlusal radiography (occlusal). Radiation exposure was 55.43 mSV with CT, 36.84-10.56 mSV with 3DX-FPD, 16.89 mSV with panorama and 0.87 mSV with occlusal. Compared to CT, radiation exposure with 3DX-FPD was markedly smaller. In addition, 3DX-FPD appears clinically useful for orthodontics because of its high resolution, superior anti-artifact measures, and clear imaging.}, pages = {61--64}, title = {歯科用小型X線CT装置による上顎前歯部 : 撮影時の頭頚部被曝線量の軽減効果}, volume = {35}, year = {2008} }