{"created":"2023-05-15T14:19:27.888723+00:00","id":3553,"links":{},"metadata":{"_buckets":{"deposit":"4f357b1e-5670-46eb-a50d-aa426c7f0ad6"},"_deposit":{"created_by":3,"id":"3553","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"3553"},"status":"published"},"_oai":{"id":"oai:ohu-lib.repo.nii.ac.jp:00003553","sets":["90:217:218"]},"author_link":["12118","12119","12120","12117"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1号","bibliographicPageStart":"A1-A8","bibliographicVolumeNumber":"37巻","bibliographic_titles":[{"bibliographic_title":"奥羽大学歯学誌"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Twin Block Appliance装着直後の前頭前野における脳活動について検討した。男子学生20例を対象とし、顔貌診査によって下顎後退の見られたClass II div.1である10例をClass II群、個性正常咬合を示し顔貌が整っている10例をClass I群とした。大脳皮質前頭前野の血流中の酸化ヘモグロビン濃度計測により、TBA装着に伴う不快感情の抽出は可能で、装着時に不快感情が生じるが、下顎前進による不快感情の増加は認めなかった。TBA装着患者の不快感情をモニターすることで、臨床上、有益となることが示唆された。","subitem_description_type":"Abstract"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-2313","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"吉永, 聡"}],"nameIdentifiers":[{"nameIdentifier":"12117","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"廣瀬, 将邦"}],"nameIdentifiers":[{"nameIdentifier":"12118","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村, 真治"}],"nameIdentifiers":[{"nameIdentifier":"12119","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"氷室, 利彦"}],"nameIdentifiers":[{"nameIdentifier":"12120","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2014-05-19"}],"displaytype":"detail","filename":"S37(1)A1-A8.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"S37(1)A1-A8.pdf","url":"https://ohu-lib.repo.nii.ac.jp/record/3553/files/S37(1)A1-A8.pdf"},"version_id":"5b1c0d87-c4bc-4c8b-a558-e01c67201d21"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"下顎後退症(治療); 咀嚼; チューインガム; 不正咬合-アングルII級(治療); *機能的顎矯正装置; *前前頭皮質","subitem_subject_scheme":"Other"},{"subitem_subject":"視覚アナログ尺度","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト; 成人(19~44); 男; 歯学","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Twin Block Appliance装着直後の前頭前野における脳活動","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Twin Block Appliance装着直後の前頭前野における脳活動"}]},"item_type_id":"10002","owner":"3","path":["218"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-05-19"},"publish_date":"2014-05-19","publish_status":"0","recid":"3553","relation_version_is_last":true,"title":["Twin Block Appliance装着直後の前頭前野における脳活動"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-15T18:26:14.193677+00:00"}