{"created":"2023-05-15T14:19:40.902654+00:00","id":3809,"links":{},"metadata":{"_buckets":{"deposit":"ef0596c6-ee58-425b-9853-dc235ca7e547"},"_deposit":{"created_by":3,"id":"3809","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"3809"},"status":"published"},"_oai":{"id":"oai:ohu-lib.repo.nii.ac.jp:00003809","sets":["90:231:234"]},"author_link":["12942"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2号","bibliographicPageStart":"57-68","bibliographicVolumeNumber":"39巻","bibliographic_titles":[{"bibliographic_title":"奥羽大学歯学誌"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"表面処理法の違いによるジルコニアとハイブリッドセラミックスとの接着強さを比較検討した。表面処理法のうち、イトロ処理単独を除いた処理法においては、対照群と比較して初期接着強さは向上した。ロカテックシステム、イトロ処理+シランカップリング処理は、他の処理法と比較して有意に高い接着強さを示した。アルミナサンドブラスト処理、シランカップリング処理、イトロ処理を単独で行った場合は、サーマルサイクル試験中に全ての試料が接着面で剥離した。ロカテックシステム、イトロ処理+シランカップリング処理を行った場合のサーマルサイクル試験後の接着強さは有意に低下した。以上より、ロカテックシステム、イトロ処理+シランカップリング処理はジルコニアとハイブリッドセラミックスの接着に有効な表面処理法であることが示唆された。","subitem_description_type":"Abstract"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-2313","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"宮地, 克佳"}],"nameIdentifiers":[{"nameIdentifier":"12942","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2014-09-12"}],"displaytype":"detail","filename":"S39(2)57-68.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"S39(2)57-68.pdf","url":"https://ohu-lib.repo.nii.ac.jp/record/3809/files/S39(2)57-68.pdf"},"version_id":"09c0dc23-7b8a-48ec-9e08-a6ed2cac611e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"*セラミック; X線分光法; *Zirconium; 走査型電子顕微鏡検査法; コンポジットレジン; *歯牙接着法; 歯科材料; 接着強さ","subitem_subject_scheme":"Other"},{"subitem_subject":"*Zirconium Oxide; カップリング剤; 表面処理","subitem_subject_scheme":"Other"},{"subitem_subject":"歯学","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"表面処理法の違いによるジルコニアとハイブリッドセラミックスの接着強さ","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"表面処理法の違いによるジルコニアとハイブリッドセラミックスの接着強さ"}]},"item_type_id":"10002","owner":"3","path":["234"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-09-12"},"publish_date":"2014-09-12","publish_status":"0","recid":"3809","relation_version_is_last":true,"title":["表面処理法の違いによるジルコニアとハイブリッドセラミックスの接着強さ"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-15T17:53:35.269675+00:00"}