{"created":"2023-05-15T14:19:43.039147+00:00","id":3855,"links":{},"metadata":{"_buckets":{"deposit":"f1518d54-8f8f-414b-b6bf-9a2ca176ca31"},"_deposit":{"created_by":3,"id":"3855","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"3855"},"status":"published"},"_oai":{"id":"oai:ohu-lib.repo.nii.ac.jp:00003855","sets":["90:231:239"]},"author_link":["13106","13104","13102","13100","13105","13098","13099","13101","13103"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2012-12","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4号","bibliographicPageStart":"231-239","bibliographicVolumeNumber":"39巻","bibliographic_titles":[{"bibliographic_title":"奥羽大学歯学誌"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"小型血液ガス分析装置のABL77(ラジオメーター社)とi-stat 300(扶桑薬品工業)の精度について検討するため、全身麻酔患者8名から採取した動脈血45検体を用い、従来の据え置き型血液ガス分析装置ABL510(ラジオメーター社)と比較した。精度評価として系列ごとの全データから標準誤差を求め、その範囲から逸脱したデータの割合を逸脱率とした。各装置によるpH、PaCO2、PaO2、SaO2、HCO3-、Hb、Na+、K+、Ca2+の測定結果を検体ごとに列記し、逸脱率および平均値を示した。総合的な逸脱率は、ABL510が4%で、ABL77は1%、i-statは0.3%であった。なおNa+、K+、Ca2+は新型2機種でのみ計測可能のため、逸脱率の比較は出来なかった。i-statはHbの検査において2.2%の逸脱がみられたのみで、酸塩基平衡や血液ガス分析での逸脱は全くなかった。","subitem_description_type":"Abstract"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-2313","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小松, 泰典"}],"nameIdentifiers":[{"nameIdentifier":"13098","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田, 健司"}],"nameIdentifiers":[{"nameIdentifier":"13099","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"冨田, 修"}],"nameIdentifiers":[{"nameIdentifier":"13100","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福島, 雅啓"}],"nameIdentifiers":[{"nameIdentifier":"13101","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"八木下, 健"}],"nameIdentifiers":[{"nameIdentifier":"13102","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤沼, 龍一"}],"nameIdentifiers":[{"nameIdentifier":"13103","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 史彦"}],"nameIdentifiers":[{"nameIdentifier":"13104","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川合, 宏仁"}],"nameIdentifiers":[{"nameIdentifier":"13105","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山崎, 信也"}],"nameIdentifiers":[{"nameIdentifier":"13106","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2014-10-16"}],"displaytype":"detail","filename":"S39(4)231-239.pdf","filesize":[{"value":"2.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"S39(4)231-239.pdf","url":"https://ohu-lib.repo.nii.ac.jp/record/3855/files/S39(4)231-239.pdf"},"version_id":"c24e7596-6b92-4195-93e6-155d58a4ecc3"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Calcium(血液); Potassium(血液); Sodium(血液); *機器と資材用品; *血液ガス分析; Hemoglobins; 酸素(血液); 水素イオン濃度; 重炭酸塩; 二酸化炭素(血液)","subitem_subject_scheme":"Other"},{"subitem_subject":"動脈血酸素分圧","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト; 歯学","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"小型血液ガス分析装置の比較使用経験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"小型血液ガス分析装置の比較使用経験"}]},"item_type_id":"10002","owner":"3","path":["239"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-10-16"},"publish_date":"2014-10-16","publish_status":"0","recid":"3855","relation_version_is_last":true,"title":["小型血液ガス分析装置の比較使用経験"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-15T15:31:53.464049+00:00"}