{"created":"2023-05-15T14:19:43.911669+00:00","id":3874,"links":{},"metadata":{"_buckets":{"deposit":"54d20dbd-4c8e-4a94-987c-744497f5b539"},"_deposit":{"created_by":3,"id":"3874","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"3874"},"status":"published"},"_oai":{"id":"oai:ohu-lib.repo.nii.ac.jp:00003874","sets":["90:241:242"]},"author_link":["13122","13120","13121"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1号","bibliographicPageStart":"31-38","bibliographicVolumeNumber":"40巻","bibliographic_titles":[{"bibliographic_title":"奥羽大学歯学誌"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"2種類(DECSY・GN-1)のCAD/CAMシステムを用い、チタン(Ti)とセラミックスを切削加工したコーピングの適合精度についてセメントスペース(スペーサー)との関連で検討した。DECSYで作製したコーピングでは、スペーサー35μm条件・55μm条件とも軸側部でセラミックブロック(DC3、DC5)に比べTiブロック(DT3、DT5)で有意に小さく、他の測定部位(マージン部、隅角部、咬合面部)で有意差はなかった。DT3とDT5の間、DC3とDC5の間に有意差はなかった。GN-1で作製したコーピングでは、スペーサー30μm条件でマージン部、咬合面部ではセラミックブロックGC3に比べTiブロックGT3で有意に小さく、軸側部ではGT3が有意に大きかった。隅角部で有意差はなかった。スペーサー50μm条件では軸側部でGT5が有意に大きく、その他の測定部位で有意差はなかった。測定部位ごとの適合精度は咬合面部で最も大きく、次いで隅角部であり、マージン部ではGC3が最も大きかった。","subitem_description_type":"Abstract"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0916-2313","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"五月女, 稔"}],"nameIdentifiers":[{"nameIdentifier":"13120","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石田, 喜紀"}],"nameIdentifiers":[{"nameIdentifier":"13121","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岡田, 英俊"}],"nameIdentifiers":[{"nameIdentifier":"13122","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2014-10-25"}],"displaytype":"detail","filename":"S40(1)31-38.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"S40(1)31-38.pdf","url":"https://ohu-lib.repo.nii.ac.jp/record/3874/files/S40(1)31-38.pdf"},"version_id":"ab01f923-8875-4883-b748-89477096219c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"*歯科材料; 分散分析; *コンピュータ支援設計; *歯科補綴物; *歯科補綴物設計; *補綴物の適合","subitem_subject_scheme":"Other"},{"subitem_subject":"*コーピング(歯科)","subitem_subject_scheme":"Other"},{"subitem_subject":"歯学","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"CAD/CAMシステムにより異なる材料を用いて製作したコーピングの適合精度","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"CAD/CAMシステムにより異なる材料を用いて製作したコーピングの適合精度"}]},"item_type_id":"10002","owner":"3","path":["242"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-10-25"},"publish_date":"2014-10-25","publish_status":"0","recid":"3874","relation_version_is_last":true,"title":["CAD/CAMシステムにより異なる材料を用いて製作したコーピングの適合精度"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-15T15:21:01.085208+00:00"}